- Clean the shaft, sleeve and bearing bore and lightly oil the sleeve's outer taper.
- Slide the sleeve onto the shaft and position it where the bearing must sit.
- Push the bearing onto the taper, then tighten the lock nut. As the bearing moves up the taper, its inner ring expands and the internal clearance falls.
- Stop at the right point. Measure the reduction in clearance with feeler gauges, or use the drive-up figures in the bearing maker's tables. Overtightening removes too much clearance and the bearing runs hot.
- Lock the nut by bending a tab of the lock washer into a slot in the nut.
- Fit the bearing into the housing base, add locating rings on the fixed end only, fill with grease as the maker advises, and fit the cap.
The cap and base of a plummer block are machined together, so never swap caps between housings.